Specifications
Depending on selected device configuration
General information
Product type |
Flowmeter |
Product series name |
OPTIFLUX |
Product positioning |
For safety instrumented systems |
Measurement principle |
Electromagnetic |
Contact to measured medium |
Yes |
Measured media |
Liquids |
Ambient temperature |
-40…+60°C / -40…+140°F Up to +65°C / +149°F with fan |
Nominal diameter / size |
DN2.5…DN2000 / …80 |
Power supply (VAC) |
85…252 VAC |
Power supply (VDC) |
24 VDC |
Operating conditions
Process pressure |
max. 40 barg/ 580 psig |
Process temperature |
-40…+180°C/ -40…+356°F |
Materials
|
Perfluoroalkoxy alkane (PFA), Polytetrafluoroethylene (PTFE), Polyuretane (PUR), Hard rubber, Ethylene tetrafluoroethylene (ETFE) |
Process connections
Flange connections |
EN (1092-1): DN2.5…2000 (larger on request) ASME (B 16.5): …80″ (larger on request) JIS (B 2220): 2.5…1000A |
Approvals/Standards
Certificates/Approvals Ex |
ATEX, IECEx |
Certificates/Approvals Safety |
SIL 2/3 |
NAMUR compliance |
NE 107, NE 21, NE 43, NE 53, NE 131 |
Communication
Analogue outputs |
4…20 mA |
Discrete outputs |
Pulse, Frequency, Status |
Digital outputs |
HART® |
Accuracy
Accuracy (liquids) |
Measuring error ±0.2% of measured value (±1 mm/s) |